Products
400 KVAR POWER FACTOR PANEL

- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- SHORT CIRCUIT LAVEL :- 35KA/50KA/65KA FOR 1SEC
- ENCLOSURE :- INDOOR/OUTDOOR USE
- TYPE :-IP55
- SHEET THICKNESS :- 2MM SHEET
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 800A ALUMINIUM
- APPLICATION :- 400KVAR POWER FACTOR PANEL
D.G + MAIN DISTRIBUTION + 200KVAR APFC PANEL

- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- FREQUENCY :- 50HZ/50HZ
- SHORT CIRCUIT LAVEL :- 35KA/50KA/65KA FOR 1SEC
- ENCLOSURE :- INDOOR/OUTDOOR USE
- TYPE :- DG TO MAIN
- SHEET THICKNESS :- 2MM SHEET
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 800A ALUMINIUM
- APPLICATION :- D.G + MAIN DISTRIBUTION + 200 KVAR APFC PANAL
500KVA D.G X2NOS + MAINX3NOS Distribution Panel

- NOOFDG:=-UPTO2
- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- FREQUENCY :- 50HZ/50HZ
- SHORT CIRCUIT LAVEL :- 35KA/50KA/65KA FOR 1SEC
- FROM:-2 to 3
- ENCLOSURE :- IN DOOR/OUTDOOR USE
- TYPE :- DG TO MAIN
- SHEET THICKNESS :- 2MM SHEET
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 2500A ALUMINIUM
- APPLICATION :- 500KVA D.G X2NOS + MAINX3NOS DISTRIBUTION PANEL
CUBICAL PANEL

- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- FREQUENCY :- 50HZ/50HZ
- SHORT CIRCUIT LAVEL :- 35KA/50KA/65KA FOR 1SEC
- ENCLOSURE :- INDOOR/OUTDOOR USE
- TYPE :- INCOMING TO OUTGOING
- SHEET THICKNESS :- 2MIM SHEET/1.6MM
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 1200A ALUMINIUM
- APPLICATION :- CUBICAL PANEL
M.C.C. PANEL

- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- FREQUENCY :- 50HZ/50HZ
- SHORT CIRCUIT LAVEL :- 35KA/50KA/65KA FOR 1SEC
- FROM :-2 TO 4
- ENCLOSURE :- INDOOR/OUTDOOR USETO 4
- TYPE :- MAIN TO MAIN
- SHEET THICKNESS :- 2MM SHEET
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 400A ALUMINIUM
- APPLICATION :- MOTOR PANEL (100HP TO 25HP )
DISTRIBUTION CUM APFC PANEL

- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- FREQUENCY :- 50HZ/50HZ
- SHORT CIRCUIT LAVEL :- 35KA/50KA/65KA FOR 1SEC
- FROM :-1 T0 5
- ENCLOSURE :- INDOOR/OUTDOOR USE
- TYPE :- MAIN TO MAIN
- SHEET THICKNESS :- 2MM SHEET
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 800A ALUMINIUM
- APPLICATION :- DISTRIBUTION CUM APFC PANEL
FIRE PANEL
- NO OF D.G :- UPTO 6
- OPERATION VOLTAGE :- 380/415/440 V3 PHASE , 4WIRE
- FREQUENCY :- 50HZ/50HZ
- SHORT CIRCUIT LAVEL :- 35KA/S0KA/65KA FOR 1SEC
- FROM :-2T0 4
- ENCLOSURE :- MAIN TO D.G
- TYPE :- DG TO MAIN
- SHEET THICKNESS :- 2MM SHEET
- POINT THICKNESS:- UPTO 100 MICRON
- BUSBAR :- 400A ALUMINIUM
APPLICATION :- FIRE PANEL (75HP S/D X2NOS,
15 HP S/D X2NOS, 12V ENGINE)